5977C Inert Plus GC/MSD
5977C GC/MSD
At Agilent we continuously strive for innovation. The new HydroInert source for hydrogen carrier applications not only minimizes disruptions from helium shortages but also improves spectral fidelity, peak shape, and sensitivity when running with hydrogen. System intelligence, like remote monitoring and email-based instrument health alerts, make system monitoring easier and more actionable. Together, these new capabilities on the 5977C GC/MSD improve sample throughput and analytical performance, enabling better business outcomes for your lab.
- GC/MS Instruments
Product Details
- Detection limits as low as 1 fg IDL assert reliability and sensitivity for your analyses
- The new HydroInert source improves chromatographic efficiency for hydrogen carrier gas applications and minimizes loss in sensitivity and spectral anomalies associated with H2 gas
- JetClean self-cleaning ion source greatly reduces or even eliminates the need for manual source cleaning
- Built-in intelligence of the 8890, 8860, and Intuvo 9000 GCs enhances productivity with smart diagnostics, monitoring, and simplified access to powerful operations through the integrated touch screen and browser interface
- Inert Flow Path products like columns, liners, inlets, gold seals, and ferrules improve mass spectrometry workflows and ensure inertness with every surface that touches your sample
- Agilent CrossLab Smart Alerts software uses email-based alerts to notify you when to consider replacing key consumables and when an instrument stops running anywhere in your lab; plan your preventive maintenance and monitor instrument health remotely
- MassHunter Unknowns Analysis allows you to develop new methods with fast and reliable compound identification using its ability to create custom retention time locked spectral libraries
- MassHunter Review by Exception and Compounds at a Glance simplify and speed up data analysis and review
- Cerno Bioscience MassWorks MS calibration technology enables high mass accuracy on the 5977C GC/MSD
- To enable a better-informed, sustainable choice, Agilent has partnered with My Green Lab to have the 5977C GC/MSD independently audited for their Accountability, Consistency, and Transparency (ACT) label
Dimensions (WxDxH) |
|
GC/MSD Method Compatibility |
|
IDL Sensitivity (positive) |
|
Ion Source |
|
Mass Range |
|
Mode of Operation |
|
QuickProbe Compatibility |
|
Scan Speed |
|
Software Platform |
|
Gas Chromatography Mass Spectrometry (GC-MS) Information
What is GC-MS? GC/MS combines two analytical tools to identify and measure the concentration of chemicals found in foods, consumer products, pharmaceuticals, fuels, the environment, and more. Read on to learn more about the typical components of a GC/MS instrument and its basic principle of operation.
Learn More- Application Notes
-
Analysis of Volatile Compounds Identified in Rubber Gasket Extracts Using GC/MSD and High-Resolution GC/Q-TOF
This application note establishes a process for identifying GC-amenable extractables and leachable compounds using GC/MSD and GC/Q-TOF instruments.
- Application Notes
- English
- 16 Sep 2024
- 3.27 MB
Analysis of Aldehydes in Beer by Agilent PAL 3 Autosampler and 5977C GC/MSD
This application note described a method for quantitation of 4 aldehydes (Hexanal, Furfural, Phenylacetaldehyde and Trans-2-Nonenal) responsible for off flavors in beer using the Agilent 8890/5977C GC/MSD with a PAL 3 (SPME) Autosampler.
- Application Notes
- English
- 24 Jul 2024
- 1.58 MB
Essential Oils Analysis Using GC/MS with Hydrogen and the Agilent HydroInert Source
This application note describes the conversion of a typical GC/MS method for the qualitative analysis of flavor and fragrance compounds in essential oils from helium to hydrogen.
- Application Notes
- English
- 30 Jan 2024
- 2.04 MB
Enhancing Sensitivity in Analysis of Semivolatile Organic Compounds with the Agilent 8890/5977C GC/MSD
Performance of an Agilent 8890/5977C GC/MSD in the analysis of semivolatile organic compounds (SVOCs) at both traditional and enhanced sensitivity levels.
- Application Notes
- English
- 14 Sep 2023
- 1017.13 KB
Identification of Metabolites in Porcine Serum with Hydrogen Carrier Gas
The current study focuses on the analysis of metabolites from the Agilent Fiehn 2013 GC/MS metabolomics retention time locking (RTL) library on a single quadrupole GC/MS using hydrogen as the GC carrier gas.
- Application Notes
- English
- 21 Jul 2023
- 472.77 KB
Analysis of Terpenes in Cannabis with Hydrogen Carrier Gas and the Agilent HydroInert Source on the Agilent 8890/5977C GC/MS
This application note summarizes the analysis of terpenes in cannabis using GC/MS with hydrogen carrier gas and the Agilent HydroInert source.
- Application Notes
- English
- 13 Jul 2023
- 308.46 KB
Analysis of Terpenes in Cannabis with Hydrogen Carrier Gas
This application note summarizes the analysis of terpenes in cannabis using gas chromatography/mass spectrometry with hydrogen carrier gas.
- Application Notes
- English
- 08 Jun 2023
- 397.37 KB
Analysis of PAHs Using GC/MS with Hydrogen Carrier Gas and the Agilent HydroInert Source
This application note focuses on GC/MS in selected ion monitoring (SIM) mode using hydrogen as the GC carrier gas.
- Application Notes
- English
- 07 Mar 2023
- 653.69 KB
Volatile Organic Compounds Analysis in Drinking Water with Headspace GC/MSD using Hydrogen Carrier Gas and HydroInert Source
See how we identified and quantitated volatiles at low µg/L levels by performing a 7-minute analysis using headspace-GC/MSD with HydroInert and hydrogen carrier gas.
- Application Notes
- English
- 08 Jul 2022
- 560.14 KB
Analysis of Semivolatile Organic Compounds Using Hydrogen Carrier Gas and HydroInert Source by Gas Chromatography/Mass Spectrometry
This application note demonstrates the ability of the Agilent HydroInert source to allow the use of hydrogen carrier gas, while retaining critical functional groups.
- Application Notes
- English
- 28 Jun 2022
- 468.55 KB
- Brochures
- Case Studies
- Flyers
- Posters
- Technical Overviews
- FAQs
-
Instrument Detection Limit Frequently Asked Questions (FAQ)
An Introduction to Using Instrument Detection Limit as a Performance Metric
How do I Troubleshoot 597x NCI Tune Problems in MassHunter?
How do I Troubleshoot 597x NCI Tune Problems in MassHunter?
Can I Run My Instrument with a High Vacuum Reading of 9.99x10-9?
Can I Run My Instrument with a High Vacuum Reading of 9.99x10-9?
FAQ: Can Hydrogen be Use Instead of Helium for My GCMSD?
FAQ: I want to change our GCMSD lab carrier gas over to hydrogen. Is it as easy as just changing the tank or is there more to consider?
KB000390: What does error ''Difficulty with mass filter electronics, cannot achieve constant peak widths'' indicate?
Information relating to error message Difficulty with mass filter electronics, cannot achieve constant peak widths''
- Site Preparation Checklists
- User Manuals
More help is just a click away.
If you didn’t find what you need, try these resources or contact a specialist.
Essential Supplies for GC/MS Workflows
These top supplies are recommended by Agilent technical experts to optimize your GC/MS workflows.
GC Productivity Tools
Download method translation software plus calculators for vapor volume, pressure flow, solvent vent, and CFT.
Helium Conservation Cost Savings Calculator
See how much helium and money you could save using Gas Saver and a helium conservation module for nitrogen standby.
Agustin Pierri, Ph.D.
Laboratory Technical Director, Weck Laboratories, Inc.
"Agilent gave us the best performance meaning the most sensitivity, the best reliability, but also the best value."
View MoreJean-Marie Beusen
Senior Scientific Advisor, Nelson Labs
“We chose Agilent as our main instrument vendor, because simply they are good instruments.”
View MoreVideos
Agilent Launches New J&W Ultra Inert Columns with Ultra Low-Bleed Technology
The new J&W 5Q columns combine Agilent's industry-leading Ultra Inert performance with Ultra Low-Bleed technology, delivering the new standard for MS column performance and productivity. 5Q columns provide exceptional peak symmetry and minimal column bleed enabling high sensitivity, mass spectral integrity, and accurate quantitation for the most challenging, trace-level analytes. 5Q columns are also designed to optimize sample throughput with fast conditioning and outstanding durability even at high operating temperatures.
- 01 Aug 2024
Agilent Announces Cutting-Edge Advances in GC/MS and LC/Q-TOF Technology at ASMS 2024
Agilent is introducing two new products. The Agilent 7010D Triple Quadrupole GC/MS System (7010D GC/TQ) features the new HES 2.0 ion source, providing attogram-level sensitivity, unmatched robustness, and industry-leading uptime. The Agilent ExD Cell available for the 6545XT AdvanceBio LC/Q-TOF enhances peptide and protein characterization capabilities by adding electron capture dissociation (ECD).
- 06 Jun 2024
eBook Showcases How Agilent GC and GC/MS Systems Can Help Labs Meet Their Sustainability Goals
Access infographics, ACT labels, ESG reports, videos and more to learn how Agilent keeps sustainability in mind during the entire instrument lifecycle, from design to decommissioning. We are dedicated to helping you lower your environmental impact while maintaining lab efficiency and productivity.
- 08 Apr 2024