1260 Infinity II SFC System - Ordering Details
如需订购或获取更多包括价格和供货情况的详细信息,请联系您当地的安捷伦客户服务中心(800-820-3278,手机用户请拨打 400-820-3278)或授权代理商,或索取报价单。
说明 | 产品/部件号 |
Agilent 1260 Infinity II SFC 控制模块 Includes CO2 booster pump and back-pressure regulator for solvent pre- and post-conditioning |
G4301A |
Accessory Kit for 1260 Infinity II SFC System Includes column connection capillary (380 x 0.17 mm), Rx-SIL analytical HPLC column, SFC connector tubing, ERI-APG cable |
G4301-68715 |
SFC/LC Checkout Sample One 2-mL ampule, methanol as solvent |
5190-0584 |
Agilent 1260 Infinity II SFC Binary Pump Maximum pressure 600 bar. Includes integrated two-channel degassing unit, solvent-selection valve, seal wash, solvent cabinet, solvent bottles and CAN cable. |
G4782A |
用于 1260/1290 Infinity II LC 的 HPLC 系统工具包 | G4782A#001 |
1260 Infinity II Max-Uptime Kit Includes stainless steel capillaries, PEEK tubing and fittings, cutter, PTFE frits, and solvent inlet filter. |
G4782A#007 |
Agilent Lab Advisor Advance Software | G4782A#004 |
不配置溶剂柜 | G4782A#960 |
Agilent 1260 Infinity II SFC Multisampler Maximum pressure 600 bar. For use with microtiter plates and individual sample containers. Separate position for five 2 mL reference vials. Includes one dual-height drawer, two 54 vial containers, and three double-height drawer substitutes to cover the drawer slots not in use. |
G4767A |
样品冷却器 Cooling unit for SFC Multisampler. Slide-in device, customer installable. Compressor-based cooler with high-performance cooling. Unit is not a thermostat and does not provide heating. |
G4767A#100 |
单层高抽屉套装 Includes 2 single-height drawers. Each drawer holds 2 sample containers for shallow microtiter plates (96 or 384 wells). The SFC Multisampler holds a maximum of 8 single-height drawers. |
G4767A#131 |
双层高抽屉套装 Includes 1 dual-height drawer. Each drawer holds 2 sample containers for:
|
G4767A#132 |
三层高抽屉套装 包括 2 个三层高抽屉。每个抽屉可容纳 2 个以下类型的样品容器:
|
G4767A#133 |
Agilent 1260 Infinity II Multicolumn Thermostat | G7116A |
增加阀驱动选件 | G7116A#058 |
Add option for one InfinityLab Quick Connect heat exchanger large id and four column holder clips | G7116A#062 |
Add option for one InfinityLab Quick Connect heat exchanger large id HF (2.5 mL/min and higher) and four column holder clips | G7116A#063 |
加热室分隔器 | G7116-60006 |
Four-column selector valve head, 600 bar, for use in G7116A | G4237A |
Agilent 1260 Infinity II Diode Array Detector WR | G7115A |
SFC low-dispersion flow cell | G7115A#021 |
SFC standard flow cell | G7115A#023 |
Agilent 1260 Infinity II Multi Wave Length Detector | G7165A |
SFC low-dispersion flow cell | G7165A#021 |
SFC standard flow cell | G7165A#023 |
Agilent 1260 Infinity II Hybrid SFC/UHPLC System Add-on to the G4301A, G4782A, G4767A, G7116A, G7115A (or G7165A). You can select from the following components: |
|
1290 Infinity 阀驱动 | G1170A |
InfinityLab Quick Change 2-position/10-port valve | G4232B |
1290 Infinity 阀驱动 | G1170A |
InfinityLab Quick Change 2-position/10-port valve | G4232B |
Any of the following 1260/1290 Infinity II Pumps: | |
1260 Infinity II 等度泵 | G7110B |
1260 Infinity II 二元泵 | G7112B |
1260 Infinity II 四元泵 | G7111B |
1290 Infinity II 全能泵 | G7104A |
1290 Infinity II 高速泵 | G7120A |
Agilent 1260 Infinity II Hybrid SFC/MS System Add-on to the G4301A, G4782A, G4767A, G7116A, G7115A (or G7165A), and 6000 Series LC/MS. You can select from the components listed below. |
|
Agilent SFC MS Connection / Splitter Kit SFC/MS connection/splitter kit for 6100 Series Single Quadrupole LC/MS, 6400 Series Triple Quadrupole LC/MS, 6200 Series Time-of-Flight LC/MS, 6500 Series Quadrupole Time-of-Flight LC/MS, Agilent 1260 Infinity II or 1290 Infinity II ELSD. |
G4309-68715 |
1260 Infinity II 等度泵 For make-up flow |
G7110B |