Skip to main content

1260 Infinity II Multisampler 订购详情

如需提交订单或了解更多订购信息(包括报价和供货情况),请联系您当地安捷伦客户服务中心或经销商,索取报价单

Agilent 1260 Infinity II Multisampler Instrument

说明 产品/部件号 备注
1260 Infinity II Multisampler
Designed for low carryover of up to 800 bar, handles well plates and individual sample containers (for example, vials, Eppendorf tubes). Includes:
  • One double-height drawer for two individual sample containers and three double-height drawer-substitutes to cover the remaining drawer-slots
  • Single needle setup with 100 µL loop and 100 µL
  • 标准针头冲洗口和蠕动泵
  • Separate position for five 2 mL reference vials
G7167A
样品冷却器
Cooling unit for 1260 Infinity II Multisampler (G7167A and B). Fits inside the Multisampler, as slide-in device (not a separate module).
G7167A #100 具有高效冷却功能的压缩机冷却装置。不是恒温器,不能加热!
1260 Infinity II Dual-Needle Option
Offers a second flow path with needle, seat and loop for parallel operation. Default flow path is two 100 µL loops plus one 100 µL analytical head
G7167A #111 For alternating quantitative injections, identical loop volumes are required! Variable volumes need to be purchased and added separately.
1260 Infinity II Multiwash Option
Minimizes carryover adding a high-performance pump for three different solvents plus a solvent selection valve. An extra high-pressure flush head is included to allow for active needle seat back flush.
G7167A #112

Multisampler Drawers for the Agilent 1260 Infinity II Multisampler
In the Agilent 1260 Infinity II Multisampler, a mix of drawer types is allowed which, however, needs to result in a total height of eight units (for example, four double-height drawers; three double-height and two single-height drawers; etc). Drawer slots not used must be closed using double-height substitute-drawers. Three double-height substitute-drawers are included with G7167A. Drawers can be easily exchanged or added to the Multisampler onsite.

说明 产品/部件号 备注
Single-Height Drawer (1H)
Quantity 2.
Each drawer can hold two individual sample containers for:
Shallow well plates (96 or 384 well plates)
G7167A #131 Maximum setup with single-height drawers is eight per instrument.
Dual-Height Drawer (2H)
Quantity 1.
Each drawer can hold two individual sample containers for:
  • 浅孔板(96 孔板或 384 孔板)
  • 深孔板(96 孔板或 384 孔板)
  • 40x 2 mL vial container
  • 54x 2 mL vial container (6/pk)
  • 27x 0.5 or 1.5 or 2 mL Eppendorf safe-lock tubes
G7167A #132 Maximum setup with double-height drawers is four per instrument.
Triple-Height Drawer (3H)
Quantity 2.
Each drawer can hold two individual sample containers for:
  • 浅孔板(96 孔板或 384 孔板)
  • 深孔板(96 孔板或 384 孔板)
  • 40x 2 mL vial container
  • 54x 2 mL vial container
  • 27x 0.5 or 1.5 or 2 mL Eppendorf safe-lock tubes
  • 用于 96 x 1 mL 加盖样品瓶的深孔板
  • 15x 6 mL vial container
G7167A #133 Maximum setup with triple-height drawers is two per instrument

Analytical Heads and Sample Loops for the Agilent 1260 Infinity II Multisampler
The Agilent 1260 Infinity II Multisampler offers great flexibility in sample injection volumes. Different options exist for standard (single-needle) instruments and dual-needle equipped instruments (option #111). Standard (single-needle) instruments always use the right-side flow path (for example, loop-right). Dual-needle instruments require two loops and needles (right and left).

说明 产品/部件号 备注
Analytical Head 40 µL
40 µL metering device for use at up to 600 bar.
G7167A #162 仅在进样量少的情况下可减少延迟体积
Analytical Head 900 µL
用于最大压力 400 bar 下大量一次进样的 900 µL 计量装置
G7167A #163 仅用于单针头设置。
限制系统压力至 400 bar。
Sample Loop-Flex 20 µL Right (only for single-needle)
For maximum 20 µL injection.
G7167A #148 Decrease delay volume of a default 100 µL loop.
Loop 20 µL Right Dual-Needle
Calibrated dual-needle loop right.
G7167A #143 Decrease delay volume of a default 100 µL dual-needle loop.
Loop 20 µL Left Dual-Needle
Calibrated dual-needle loop left.
G7167A #149 Decrease delay volume of a default 100 µL loop.
Sample Loop-Flex 40 µL Right (only for single-needle)
For maximum 40 µL injection.
G7167A #150 Decrease delay volume of a default 100 µL loop.
Loop 40 µL Right Dual-Needle
Calibrated dual-needle loop right.
G7167A #144 Decrease delay volume of a default 100 µL dual-needle loop.
Loop 40 µL Left Dual-Needle
Calibrated dual-needle loop left.
G7167A #151 Decrease delay volume of a default 100 µL dual-needle loop.
Sample Loop-Flex 500 µL right (only for single-needle)
For maximum 500 µL injection.
  • Only in combination with 900 µL analytical head
  • Maximum pressure limitation to 400 bar
G7167A #154 Extending sample loop volume for standard path. Requires G7167A #163.
Loop Kit 500 µL Right Dual-Needle
Calibrated dual-needle loop-flex plus extension and slotted needle.
G7167A #146 Only within dual-needle setup.
Requires a 100 µL analytical head.
Loop Kit 500 µL Left Dual-Needle
Calibrated dual-needle loop-flex plus extension and slotted needle.
G7167A #155 Only within dual-needle setup. Requires a 100 µL analytical head.
Sample Loop-Flex 900 µL Right (only for single-needle) Sample loop-flex 900 µL right for maximum 900 µL injection.
  • Only in combination with 900 µL analytical head
  • Maximum pressure limitation to 400 bar
G7167A #156 Requires a 900 µL analytical head (G7167A #163). System pressure limited to maximum 400 bar.
Loop Kit 900 µL Right Dual-Needle
Calibrated dual-needle flex-loop plus extension and slotted needle.
  • Only in combination with 900 µL analytical head
  • Maximum pressure limitation to 400 bar
G7167A #147 Only within dual-needle setup dual-needle loop. Requires a 900 µL analytical head (G7167A #163). System pressure limited to maximum 400 bar
Loop Kit 900 µL Left Dual-Needle
Calibrated dual-needle flex-loop plus extension and slotted needle.
  • Only in combination with 900 µL analytical head
  • Maximum pressure limitation to 400 bar
G7167A #157 Requires a 900 µL analytical head (G7167A #163). System pressure limited to maximum 400 bar.