JetClean 智氢洁离子源
Agilent JetClean 离子源利用软件控制的氢气流来减少或防止污染物积聚并消除离子源中的基质沉积物。JetClean 的自动清洁离子源功能不仅可以延长仪器的正常运行时间,还可以生成更加一致的数据、减少重复工作,让您在节省成本的同时对结果更加充满信心。
- GC/MS 离子源和进样口
产品详细信息
- 手动清洁频率降低 80% 或更多(取决于具体应用),显著延长免维护运行周期
- 显著缩短甚至消除仪器在放空、拆卸、清洁、重新组装、重新调谐和重新校准上所耗费的时间,延长仪器正常运行时间,减少操作人员的工作量,从而提高效率
- 无需人工干预,即可在预设时间点自动激活 JetClean,例如在空闲时间段内
- 使用采集和清洁(并行)模式在分析期间进行清洁,或使用仅清洁(运行后)模式,仅在系统需要清洁时,在采集后引入氢气进行清洁
- 仅需消耗极少的 H2。氢气可以通过气阀瓶等多种方式提供。
- 操作均由 Agilent MassHunter 软件控制,从而可轻松实现采集控制、方法开发、定性和定量分析以及报告。单四极杆仪器也由 OpenLab 2.3 软件进行类似控制
- 适用于 Agilent 5977C、7000E 和 7010D GC/MS 系统。Agilent Intuvo、8890 和 7890 GC 也可兼容 JetClean 运行
- 可作为现有 Agilent 5975、5977、7000 和 7010 气质联用系统的升级
- 重要资料
-
Agilent JetClean self-cleaning ion source for GC/MS e-book
Save Time and Money with the Agilent JetClean Self-Cleaning Ion Source for GC/MS
- 产品样本
- English
- 2021 年 5 月 5 日
- 642.18 KB
- 应用简报
- 产品样本
- 案例研究
- 宣传单页
- 挂图
Dr. Noga Sikron Persi, PhD
Ben-Gurion University Metabolomics Laboratory
"The nature of our work meant we had to clean the ion source on our previous, non-Agilent GC/MS about once every 2 weeks. Since we started using the Agilent GC/MSD with JetClean, the source has been cleaned once in 9 months meaning our instrument spends more time running samples and generating data—and our users spend less time having to remove, clean, and reinstall the source. JetClean has been a tremendous benefit on instrument uptime and lab productivity."
查看更多Jana Pulkrabova, Ph. D.
Head of the Department of Food Analysis and Nutrition, University of Chemistry and Technology, Prague
"Our laboratory carries out pesticide residue analysis with the Agilent 7000 GC/MS/MS. The samples include common fruits and vegetables, but we also analyze more difficult herbal samples, and monitor baby food, which has lower detection requirements. To satisfy SANCO defined QA/QC specifications with these varied samples, the GC/MS source usually had to be cleaned every 2 weeks. After installing the JetClean system, the frequency of the manual source cleaning has been greatly reduced, we now manually clean the source only once in every 3 months. This increased productivity and freed up operator time is greatly appreciated."
查看更多Klaus Wilmers, PhD
Chemical and Veterinary Analytical Institute Muensterland-Emscher-Lippe (CVUA-MEL), Muenster, Germany
"We analyzed the EN QuEChERS in various food extracts – e.g. chard, apple, plum, peppers and spinach in the working range of 0.1 – 250 ppb (in vial) using internal standards, Analyte Protectants and employing the high efficiency source. Without JetClean, manual source cleaning was needed after 200-300 matrix runs. Applying JetClean after each run, manual cleaning was only needed after 600-900 matrix runs, thus, instrument up-time was increased by several-fold and associated cost-savings were realized."
查看更多