Refine Results
- Technique
-
Publication Technique
- Analysis Platform
-
Product
- Research Area
-
Research Area
No results found for “XXX”
Try modifying your search
- Try to search without any filters
- Try different keywords
- Try more general and fewer keywords
- Make sure all keywords are spelled correctly
- Assay
-
Assay
No results found for “XXX”
Try modifying your search
- Try to search without any filters
- Try different keywords
- Try more general and fewer keywords
- Make sure all keywords are spelled correctly
- Reagent
-
Reagent
- Cell Type
-
Cell Type
No results found for “XXX”
Try modifying your search
- Try to search without any filters
- Try different keywords
- Try more general and fewer keywords
- Make sure all keywords are spelled correctly
- Cell Line
-
Cell Line
No results found for “XXX”
Try modifying your search
- Try to search without any filters
- Try different keywords
- Try more general and fewer keywords
- Make sure all keywords are spelled correctly
- Species
-
Species
Agilent Life Science Publication Database
The Agilent Life Science Publication Database provides an easy way to search scientific publications that reference and/or cite Agilent products. Search publications by research area, cell type, cell line, instrument, assay, or author. The resulting publications can be reviewed with links to the abstract, in the Quick View, or be exported in MS Excel format and reviewed offline at a later time. (Click on the Download Results button to compile the results)For Research Use Only. Not for use in diagnostic procedures.
- Journal: Nat Commun
- Publication Date: 08 June 2022
- Author: Lin S , et al.
103015-100+103344-100+103708-100+103710-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
Authors | Lin S, Zhang, A, Yuan, L, Wang, Y, Zhang, C, Jiang, J, Xu, H, Yuan, H, Yao, H, Zhang, Q, Zhang, Y, Lou, M, Wang, P, Zhang, ZN and Luan, B |
---|---|
Journal | Nat Commun |
Publication Date | 08 June 2022 |
Research Area(s) include | Immunology Research |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XFe24/XF24 |
Mode | N/A |
Cell Line(s) include | Brown adipose tissue (BAT), Muscle tissue, White adipose tissue (WAT) |
Cell Type(s) include | Adipose Tissue, Muscle cells |
Species | Mouse |
Assay / Method | Cell Mitochondrial Stress Test, Glycolytic Rate Assay |
Cell Seeding Density | 4 mg/well |
Plate Coating | Not Specified |
- Journal: Cell Metab
- Publication Date: 07 June 2022
- Author: Zhou N , et al.
103015-100+103344-100+103708-100+103710-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
Authors | Zhou N, Qi, H, Liu, J, Zhang, G, Liu, J, Liu, N, Zhu, M, Zhao, X, Song, C, Zhou, Z, Gong, J, Li, R, Bai, X, Jin, Y, Song, Y and Yin, Y |
---|---|
Journal | Cell Metab |
Publication Date | 07 June 2022 |
Research Area(s) include | Obesity, Diabetes, and Metabolic Disorders |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XFe24/XF24 |
Mode | N/A |
Cell Line(s) include | 3T3-L1 |
Cell Type(s) include | Fibroblast |
Species | Mouse |
Assay / Method | Cell Mitochondrial Stress Test, Glycolytic Rate Assay |
Cell Seeding Density | 2.0x10^4 cells/well |
Plate Coating | Not Specified |
- Journal: Nat Commun
- Publication Date: 07 June 2022
- Author: Han JS , et al.
103015-100+103708-100
Seahorse XF 96 well (XF Pro/XFe96/XF96)|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xf-pro-analyzer-1980223
Authors | Han JS, Jeon, YG, Oh, M, Lee, G, Nahmgoong, H, Han, SM, Choi, J, Kim, YY, Shin, KC, Kim, J, Jo, K, Choe, SS, Park, EJ, Kim, S and Kim, JB |
---|---|
Journal | Nat Commun |
Publication Date | 07 June 2022 |
Research Area(s) include | Cell Physiology Research |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XF 96 well (XF Pro/XFe96/XF96) |
Mode | N/A |
Cell Line(s) include | Beige adipocytes |
Cell Type(s) include | Adipocytes |
Species | Mouse |
Assay / Method | Cell Mitochondrial Stress Test |
Cell Seeding Density | Not Specified |
Plate Coating | Not Specified |
- Journal: Toxicol Appl Pharmacol
- Publication Date: 06 June 2022
- Author: Abu Bakar MH , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
Authors | Abu Bakar MH, Nor Shahril, NS, Mohamad Khalid, MSF, Mohammad, S, Shariff, KA, Karunakaran, T, Mohd Salleh, R and Mohamad Rosdi, MN |
---|---|
Journal | Toxicol Appl Pharmacol |
Publication Date | 06 June 2022 |
Research Area(s) include | Obesity, Diabetes, and Metabolic Disorders |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XFe24/XF24 |
Mode | N/A |
Cell Line(s) include | Isolated mitochondria, Myotubes |
Cell Type(s) include | Myotubes |
Species | Mouse |
Assay / Method | Cell Mitochondrial Stress Test |
Cell Seeding Density | 5.0x10^6 cells/well |
Plate Coating | Not Specified |
- Journal: Bioact Mater
- Publication Date: 04 June 2022
- Author: Wu P , et al.
103015-100+103708-100
Seahorse XF 96 well (XF Pro/XFe96/XF96)|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xf-pro-analyzer-1980223
Authors | Wu P, Sai, X, Li, Z, Ye, X, Jin, L, Liu, G, Li, G, Yang, P, Zhao, M, Zhu, S, Liu, N and Zhu, P |
---|---|
Journal | Bioact Mater |
Publication Date | 04 June 2022 |
Research Area(s) include | Cardiovascular Research, Stem Cell Biology |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XF 96 well (XF Pro/XFe96/XF96) |
Mode | N/A |
Cell Line(s) include | iPSC-derived cardiomyocytes |
Cell Type(s) include | Cardiac cells |
Species | Rat |
Assay / Method | Cell Mitochondrial Stress Test |
Cell Seeding Density | 3.0x10^4 cells/well |
Plate Coating | Not Specified |
- Journal: iScience
- Publication Date: 03 June 2022
- Author: McGowan ENS , et al.
103015-100+103708-100
Seahorse XF 96 well (XF Pro/XFe96/XF96)|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xf-pro-analyzer-1980223
Authors | McGowan ENS, Wong, O, Jones, E, Nguyen, J, Wee, J, Demaria, MC, Deliyanti, D, Johnson, CJ, Hickey, MJ, McConville, MJ, Wilkinson-Berka, JL, Wright, MD and Binger, KJ |
---|---|
Journal | iScience |
Publication Date | 03 June 2022 |
Research Area(s) include | Immunology Research |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XF 96 well (XF Pro/XFe96/XF96) |
Mode | N/A |
Cell Line(s) include | Bone marrow-derived macrophages (BMDM) |
Cell Type(s) include | Immune cells |
Species | Mouse |
Assay / Method | Cell Mitochondrial Stress Test |
Cell Seeding Density | 8.0x10^4 cells/well |
Plate Coating | Not Specified |
- Journal: Nat Metab
- Publication Date: 02 June 2022
- Author: He W , et al.
103015-100+103708-100
Seahorse XF 96 well (XF Pro/XFe96/XF96)|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xf-pro-analyzer-1980223
Authors | He W, Henne, A, Lauterbach, M, Geissmar, E, Nikolka, F, Kho, C, Heinz, A, Dostert, C, Grusdat, M, Cordes, T, Harm, J, Goldmann, O, Ewen, A, Verschueren, C, Blay-Cadanet, J, Geffers, R, Garritsen, H, Kneiling, M, Holm, CK, Metallo, CM, Medina, E, Abdullah, Z, Latz, E, Brenner, D and Hiller, K |
---|---|
Journal | Nat Metab |
Publication Date | 02 June 2022 |
Research Area(s) include | Immunology Research |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XF 96 well (XF Pro/XFe96/XF96) |
Mode | N/A |
Cell Line(s) include | RAW264.7 |
Cell Type(s) include | Immune cells |
Species | Mouse |
Assay / Method | Cell Mitochondrial Stress Test with additional injection |
Cell Seeding Density | 2.0x10^4 cells/well |
Plate Coating | Not Specified |
- Journal: Nat Metab
- Publication Date: 02 June 2022
- Author: Chen F , et al.
103015-100+103708-100
Seahorse XF 96 well (XF Pro/XFe96/XF96)|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xf-pro-analyzer-1980223
Authors | Chen F, Elgaher, WAM, Winterhoff, M, Bussow, K, Waqas, FH, Graner, E, Pires-Afonso, Y, Casares Perez, L, de la Vega, L, Sahini, N, Czichon, L, Zobl, W, Zillinger, T, Shehata, M, Pleschka, S, Bahre, H, Falk, C, Michelucci, A, Schuchardt, S, Blankenfeldt, W, Hirsch, AKH and Pessler, F |
---|---|
Journal | Nat Metab |
Publication Date | 02 June 2022 |
Research Area(s) include | Immunology Research |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XF 96 well (XF Pro/XFe96/XF96) |
Mode | N/A |
Cell Line(s) include | THP-1 |
Cell Type(s) include | Leukemia cells |
Species | Human |
Assay / Method | Cell Mitochondrial Stress Test |
Cell Seeding Density | 2.5x10^4 cells/well |
Plate Coating | Not Specified |
- Journal: Cell Rep
- Publication Date: 31 May 2022
- Author: Han L , et al.
103010-100
Seahorse XFp|/search/?N=1000000006&Ntt=Seahorse%20XFp%20Analyzer&redirect=0
Authors | Han L, Wang, G, Zhou, S, Situ, C, He, Z, Li, Y, Qiu, Y, Huang, Y, Xu, A, Ong, MTY, Wang, H, Zhang, J and Wu, Z |
---|---|
Journal | Cell Rep |
Publication Date | 31 May 2022 |
Research Area(s) include | Obesity, Diabetes, and Metabolic Disorders |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XFp |
Mode | N/A |
Cell Line(s) include | Muscle cells |
Cell Type(s) include | Muscle cells |
Species | Mouse |
Assay / Method | Cell Mitochondrial Stress Test |
Cell Seeding Density | 5.0x10^4 cells/well |
Plate Coating | Not Specified |
- Journal: Br J Cancer
- Publication Date: 30 May 2022
- Author: Yao X , et al.
103015-100+103020-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
Authors | Yao X, He, Z, Qin, C, Zhang, P, Sui, C, Deng, X, Fang, Y, Li, G and Shi, J |
---|---|
Journal | Br J Cancer |
Publication Date | 30 May 2022 |
Research Area(s) include | Cancer Research |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XFe24/XF24 |
Mode | N/A |
Cell Line(s) include | Gastric cancer |
Cell Type(s) include | Gastric cancer cells |
Species | Human |
Assay / Method | Cell Mitochondrial Stress Test, Glycolysis Stress Test |
Cell Seeding Density | 3.5x10^4 cells/well |
Plate Coating | Not Specified |
- Journal: Chem Sci
- Publication Date: 26 May 2022
- Author: Sohn YS , et al.
103010-100+103017-100
Seahorse XFp|/search/?N=1000000006&Ntt=Seahorse%20XFp%20Analyzer&redirect=0
Authors | Sohn YS, Losub-Amir, A, Cardenas, AE, Karmi, O, Yahana, MD, Gruman, T, Rowland, L, Marjault, HB, Webb, LJ, Mittler, R, Elber, R, Friedler, A and Nechushtai, R |
---|---|
Journal | Chem Sci |
Publication Date | 26 May 2022 |
Research Area(s) include | Cancer Research |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XFp |
Mode | N/A |
Cell Line(s) include | MDA-MB-231 |
Cell Type(s) include | Breast cancer cells |
Species | Human |
Assay / Method | Cell Mitochondrial Stress Test, Glycolysis Stress Test |
Cell Seeding Density | 4.2x10^4 cells/well |
Plate Coating | Not Specified |
- Journal: Cell Host Microbe
- Publication Date: 26 May 2022
- Author: Le HH , et al.
103015-100+103708-100
Seahorse XF 96 well (XF Pro/XFe96/XF96)|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xf-pro-analyzer-1980223
Authors | Le HH, Lee, MT, Besler, KR and Johnson, EL |
---|---|
Journal | Cell Host Microbe |
Publication Date | 26 May 2022 |
Research Area(s) include | Hepatobiology Research, Microbial Research |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XF 96 well (XF Pro/XFe96/XF96) |
Mode | N/A |
Cell Line(s) include | HepG2 |
Cell Type(s) include | Hepatocarcinoma cells |
Species | Human |
Assay / Method | Cell Mitochondrial Stress Test |
Cell Seeding Density | 2.0x10^4 cells/well |
Plate Coating | Not Specified |
- Journal: Nat Commun
- Publication Date: 26 May 2022
- Author: Kerr AG , et al.
103020-100
Seahorse XF 96 well (XF Pro/XFe96/XF96)|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xf-pro-analyzer-1980223
Authors | Kerr AG, Wang, Z, Wang, N, Kwok, KHM, Jalkanen, J, Ludzki, A, Lecoutre, S, Langin, D, Bergo, MO, Dahlman, I, Mim, C, Arner, P and Gao, H |
---|---|
Journal | Nat Commun |
Publication Date | 26 May 2022 |
Research Area(s) include | Cell Physiology Research, Obesity, Diabetes, and Metabolic Disorders |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XF 96 well (XF Pro/XFe96/XF96) |
Mode | N/A |
Cell Line(s) include | Adipocyte stem cells |
Cell Type(s) include | Stem cells |
Species | Human |
Assay / Method | Glycolysis Stress Test |
Cell Seeding Density | 1.6x10^4 cells/well |
Plate Coating | Not Specified |
- Journal: Bioengineered
- Publication Date: 26 May 2022
- Author: Zhou C , et al.
103015-100+103020-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
Authors | Zhou C, Wang, L, Hu, W, Tang, L, Zhang, P, Gao, Y, Du, J, Li, Y and Wang, Y |
---|---|
Journal | Bioengineered |
Publication Date | 26 May 2022 |
Research Area(s) include | Cancer Research |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XFe24/XF24 |
Mode | N/A |
Cell Line(s) include | SW-1990 |
Cell Type(s) include | Pancreatic cancer cells |
Species | Human |
Assay / Method | Cell Mitochondrial Stress Test, Glycolysis Stress Test |
Cell Seeding Density | Not Specified |
Plate Coating | Not Specified |
- Journal: Cell Death Dis
- Publication Date: 25 May 2022
- Author: Qiu L , et al.
103010-100+103015-100+103708-100
Seahorse XF 96 well (XF Pro/XFe96/XF96)|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xf-pro-analyzer-1980223+Seahorse XF HS Mini|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xf-hs-mini-analyzer-770502+Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878+Seahorse XFp|/search/?N=1000000006&Ntt=Seahorse%20XFp%20Analyzer&redirect=0
Authors | Qiu L, Yang, Q, Zhao, W, Xing, Y, Li, P, Zhou, X, Ning, H, Shi, R, Gou, S, Chen, Y, Zhai, W, Wu, Y, Li, G, Chen, Z, Ren, Y, Gao, Y, Zhang, Y and Qi, Y |
---|---|
Journal | Cell Death Dis |
Publication Date | 25 May 2022 |
Research Area(s) include | Cell Physiology Research |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XF 96 well (XF Pro/XFe96/XF96), Seahorse XF HS Mini, Seahorse XFe24/XF24, Seahorse XFp |
Mode | N/A |
Cell Line(s) include | HepG2 |
Cell Type(s) include | Hepatocarcinoma cells |
Species | Human |
Assay / Method | Cell Mitochondrial Stress Test |
Cell Seeding Density | Not Specified |
Plate Coating | Not Specified |
- Journal: Stem Cell Res Ther
- Publication Date: 21 May 2022
- Author: Scrima R , et al.
103015-100+103708-100
Seahorse XF 96 well (XF Pro/XFe96/XF96)|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xf-pro-analyzer-1980223
Authors | Scrima R, Agriesti, F, Pacelli, C, Piccoli, C, Pucci, P, Amoresano, A, Cela, O, Nappi, L, Tataranni, T, Mori, G, Formisano, P and Capitanio, N |
---|---|
Journal | Stem Cell Res Ther |
Publication Date | 21 May 2022 |
Research Area(s) include | Stem Cell Biology |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XF 96 well (XF Pro/XFe96/XF96) |
Mode | N/A |
Cell Line(s) include | Mesenchymal stem cells |
Cell Type(s) include | Stem cells |
Species | Human |
Assay / Method | Cell Mitochondrial Stress Test with additional injection, Cell Mitochondrial Stress Test |
Cell Seeding Density | Not Specified |
Plate Coating | Not Specified |
- Journal: Int J Cancer
- Publication Date: 21 May 2022
- Author: Madi A , et al.
103015-100+103020-100+103708-100
Seahorse XF 96 well (XF Pro/XFe96/XF96)|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xf-pro-analyzer-1980223
Authors | Madi A, Weisshaar, N, Buettner, M, Poschet, G, Ma, S, Wu, J, Mieg, A, Hering, M, Ming, Y, Mohr, K, Ten Bosch, N and Cui, G |
---|---|
Journal | Int J Cancer |
Publication Date | 21 May 2022 |
Research Area(s) include | Immunology Research |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XF 96 well (XF Pro/XFe96/XF96) |
Mode | N/A |
Cell Line(s) include | CD8+, T-cells |
Cell Type(s) include | Immune cells |
Species | Mouse |
Assay / Method | Cell Mitochondrial Stress Test, Glycolysis Stress Test |
Cell Seeding Density | Not Specified |
Plate Coating | Not Specified |
- Journal: Nat Commun
- Publication Date: 19 May 2022
- Author: Baran N , et al.
103015-100+103020-100+103592-100+103677-100+103708-100
Seahorse XF 96 well (XF Pro/XFe96/XF96)|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xf-pro-analyzer-1980223
Authors | Baran N, Lodi, A, Dhungana, Y, Herbrich, S, Collins, M, Sweeney, S, Pandey, R, Skwarska, A, Patel, S, Tremblay, M, Kuruvilla, VM, Cavazos, A, Kaplan, M, Warmoes, MO, Veiga, DT, Furudate, K, Rojas-Sutterin, S, Haman, A, Gareau, Y, Marinier, A, Ma, H, Harutyunyan, K, Daher, M, Garcia, LM, Al-Atrash, G, Piya, S, Ruvolo, V, Yang, W, Shanmugavelandy, SS, Feng, N, Gay, J, Du, D, Yang, JJ, Hoff, FW, Kaminski, M, Tomczak, K, Eric Davis, R, Herranz, D, Ferrando, A, Jabbour, EJ, Emilia Di Francesco, M, Teachey, DT, Horton, TM, Kornblau, S, Rezvani, K, Sauvageau, G, Gagea, M, Andreeff, M, Takahashi, K, Marszalek, JR, Lorenzi, PL, Yu, J, Tiziani, S, Hoang, T and Konopleva, M |
---|---|
Journal | Nat Commun |
Publication Date | 19 May 2022 |
Research Area(s) include | Cancer Research |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XF 96 well (XF Pro/XFe96/XF96) |
Mode | N/A |
Cell Line(s) include | T-cell acute lymphoblastic leukemia (T-ALL) |
Cell Type(s) include | Leukemia cells |
Species | Human |
Assay / Method | Cell Mitochondrial Stress Test, Glycolysis Stress Test, Real-Time ATP Rate Assay |
Cell Seeding Density | 2.0x10^6 cells/mL |
Plate Coating | Cell-Tak |
- Journal: Nat Commun
- Publication Date: 18 May 2022
- Author: Liu W , et al.
103015-100+103708-100
Seahorse XFe24/XF24|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xfe24-analyzer-740878
Authors | Liu W, Zhou, H, Wang, H, Zhang, Q, Zhang, R, Willard, B, Liu, C, Kang, Z, Li, X and Li, X |
---|---|
Journal | Nat Commun |
Publication Date | 18 May 2022 |
Research Area(s) include | Obesity, Diabetes, and Metabolic Disorders |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XFe24/XF24 |
Mode | N/A |
Cell Line(s) include | Adipocytes |
Cell Type(s) include | Adipocytes |
Species | Mouse |
Assay / Method | Cell Mitochondrial Stress Test |
Cell Seeding Density | 1.5-2.0x10^4 cells/well |
Plate Coating | Not Specified |
- Journal: J Hazard Mater
- Publication Date: 11 May 2022
- Author: Marques Dos Santos M , et al.
103015-100+103708-100
Seahorse XF 96 well (XF Pro/XFe96/XF96)|/en/product/cell-analysis/real-time-cell-metabolic-analysis/xf-analyzers/seahorse-xf-pro-analyzer-1980223
Authors | Marques Dos Santos M, Cheriaux, C, Jia, S, Thomas, M, Gallard, H, Croue, JP, Carato, P and Snyder, SA |
---|---|
Journal | J Hazard Mater |
Publication Date | 11 May 2022 |
Research Area(s) include | Toxicology Research |
Technique | Seahorse XF Technology |
Analyzer(s) include | Seahorse XF 96 well (XF Pro/XFe96/XF96) |
Mode | N/A |
Cell Line(s) include | A549, HepG2 |
Cell Type(s) include | Hepatocarcinoma cells, Lung cancer cells |
Species | Human |
Assay / Method | Cell Mitochondrial Stress Test |
Cell Seeding Density | 2.0x10^4 cells/well |
Plate Coating | Not Specified |