High Sensitivity RNA ScreenTape Analysis
Results are obtained quickly, as fast as 2 minutes per sample. Accurate analysis is possible with only 2 µL of sample.
The assay is compatible with all Agilent TapeStation instruments.
Note: Some products within this assay contain SYBR™ Gold, which is licensed from Life Technologies Corporation for use in research and development only. SYBR™ is a registered trademark of Life Technologies Corporation.
- TapeStation RNA ScreenTape & Reagents
Product Details
- Use the RINe quality metric to standardize your total RNA integrity assessment.
- Detect RNA samples down to 100 pg/µL, allowing assessment of samples of limited abundance.
- Use only 2 µL of RNA sample to reduce sample consumption.
- Obtain data in just two minutes per sample to minimize time to results.
- Benefit from ready-to-use ScreenTape devices, prepackaged reagents, and automated data analysis to perform your QC quickly and easily.
- Use individual ScreenTape lanes and disposable pipette tips to prevent sample carryover or cross contamination.
- Save partially used ScreenTape devices for completion at a later point in time to enable full sample scalability with constant cost-per-sample.
RINe 기능 범위 |
|
ScreenTape당 사용 횟수 |
|
분석 시간 |
|
분석 유형 |
|
시료량 |
|
시료의 최대 완충액 농도 |
|
시료의 품질 평가 점수 |
|
유효 기간 |
|
정량 범위 |
|
정량 정밀도 |
|
정량 정확도 |
|
키트당 사용 횟수 |
|
피크 감도 |
|
- Key Literature
-
RNA Quality Assessment with the Agilent Automated Electrophoresis Systems
This overview demonstrates the comparability of the Agilent automated electrophoresis instruments in assessing intact and degraded total RNA samples from various sources.
- Technical Overviews
- English
- 15 May 2024
- 720.68 KB
FFPE RNA Quality Assessment with the Agilent Bioanalyzer and TapeStation Systems
This technical overview compared the analysis of multiple FFPE RNA samples on the Agilent 2100 Bioanalyzer and Agilent TapeStation systems.
- Technical Overviews
- English
- 15 May 2024
- 542.62 KB
Performance Equivalence of RNA ScreenTape Assays on Agilent TapeStation Systems
In this technical overview, the performance equivalence of RNA ScreenTape assays on Agilent TapeStation Systems is compared, with results sugggesting full compatibility across versions.
- Technical Overviews
- English
- 04 Nov 2024
- 877.12 KB
- Application Notes
- Brochures
- Catalogs
- Data Sheets
- Technical Overviews
- FAQs
-
- User Manuals
Didn’t find what you need? Contact our support team.
Contact our sales/support team by phone or email, or join the Agilent Community to access self-help articles, connect with customers, and learn and share insights.
Videos
DV200 Analysis with the Agilent TapeStation systems
Quickly perform input quality control for your formalin-fixed, paraffin-embedded (FFPE) RNA samples.