Unparalleled GC/TQ intelligence
NEW 7010D Triple Quadrupole GC/MS
Setting itself apart, the 7010D boasts intelligent features like SWARM autotune and Agilent MassHunter Optimizer for GC/TQ, streamlining performance and method optimization for consistent and reliable data acquisition. As the market leader, Agilent is committed to more than innovation, fostering partnerships with you to navigate evolving regulatory landscapes together, staying one step ahead of key changes. The 7010D GC/TQ builds on this commitment with features designed to enable your success.
- GC/MS Instruments
Product Details
- The novel HES 2.0 ion source delivers confident attogram-level analysis even in complex matrices providing best-in-class instrument uptime.
- JetClean reduces or even eliminates the need for manual ion source cleanings, reducing instrument downtime and optimizing workflow efficiency.
- MassHunter Optimizer for GC/TQ streamlines the transfer of GC/MSD methods to GC/TQ and modernized Retention Time Locking functionality improves reproducibly after column maintenance or transferring methods between GC systems.
- Twice-as-fast SWARM autotune with incorporated diagnostic features pairs with the built-in intelligence of the 8890 and Intuvo GCs for improved system diagnostics and simplified access to powerful operations through an integrated touch screen and browser interface.
- Data acquisition modes like simultaneous dMRM and scan mode and data-dependent tMRM enable targeted screening with confident quantitation of hundreds of analytes in a single run.
- The heated hyperbolic gold quadrupole, hexapole collision cell with linear acceleration technology, and triple off-axis detector work together to provide enhanced selectivity and reduced neutral noise for optimal GC/TQ performance.
- Built-in technical and procedural controls ensure data integrity and help facilitate compliance with electronic record regulations such as US FDA 21 CFR Part 11 and EU Annex 11.
- The Agilent Pesticides and Environmental Pollutants 4.0 Database contains over 1,100 compounds with multiple transitions per compound and over 7,500 matrix-optimized MRM transitions, helping you build acquisition methods that reduce matrix interferences.
- The Agilent Reference Compound Introduction Valve enables easy analysis of environmental dioxins, while meeting the requirements and strict method detection limits of the EPA-approved alternative testing procedure.
- To enable a better-informed, sustainable choice, Agilent has partnered with My Green Lab to have the 7010D GC/TQ independently audited for the Accountability, Consistency, and Transparency (ACT) label.
Detector |
|
Dimensions (WxDxH) |
|
GC/MSD Method Compatibility |
|
IDL Sensitivity (positive) |
|
Ion Source |
|
JetClean Compatibility |
|
MRM Speed |
|
Mass Range |
|
Minimum MRM Dwell Time |
|
Mode of Operation |
|
QuickProbe Compatibility |
|
Scan Speed |
|
Software Platform |
|
Gas Chromatography Mass Spectrometry (GC-MS) Information
What is GC-MS? GC/MS combines two analytical tools to identify and measure the concentration of chemicals found in foods, consumer products, pharmaceuticals, fuels, the environment, and more. Read on to learn more about the typical components of a GC/MS instrument and its basic principle of operation.
Learn More- Application Notes
-
Ethylene Oxide and 2-Chloroethanol in Spices and Oilseeds Using QuEChERS GC/MS/MS
This application note demonstrates the use of an Agilent 8890 GC system with 7010 GC/MS to detect and quantify ethylene oxide and 2-chloroethanol in foodstuff.
- Application Notes
- English
- 16 Sep 2024
- 1.37 MB
Novel Column Chemistry Raises the Bar on Sensitivity and Data Accuracy in SVOCs Analysis
In this application note, we examine how column attributes like bleed, inertness, and thermal stability can further benefit the sensitivity and accuracy of an MS.
- Application Notes
- English
- 21 Aug 2024
- 814.34 KB
Brewing Excellence: Quantitating Over 200 Pesticides in Black Tea with Steady Performance and Maximized Uptime by GC/MS/MS
Sensitive and robust quantitation of 246 pesticides in black tea extract with the 7010D Triple Quadrupole Mass Spectrometer (GC/TQ) featuring a new second generation High Efficiency Source 2.0 (HES 2.0).
- Application Notes
- English
- 23 May 2024
- 3.11 MB
Quantification of Nitrosamine Impurities in Sartan Drugs Using an Agilent GC/TQ with Hydrogen Carrier Gas
Hydrogen carrier gas for analyzing nitrosamines in sartan drugs with Agilent 8890/7000E and 8890/7010 Series GC/TQ systems under unified compliance.
- Application Notes
- English
- 23 May 2024
- 1.21 MB
Enhanced Longevity and Revolutionized Robustness for Sensitive Detection of 190 Pesticides Over 800 Injections
Enhanced performance and sensitivity for the GC/TQ analysis of 190 pesticides over 800 injections in spinach extracts.
- Application Notes
- English
- 15 May 2024
- 1.52 MB
Multiplatform Approach for Lithium-Ion Battery Electrolyte Compositional Analysis
Multiplatform approach profiling electrolyte analysis in lithium-ion batteries using GC/TQ, LC/Q-TOF MS, and ICP-MS instrumentation.
- Application Notes
- English
- 26 Jan 2024
- 2.66 MB
Analysis of Semivolatile Compounds in Water by Low-Density Liquid-Liquid Microextraction (LDME)
SVOCs in water by low-density liquid-liquid microextraction (LDME) and Agilent 7010 TQ GC/MS.
- Application Notes
- English
- 10 Nov 2023
- 623.62 KB
Analysis of Ethylene Oxide and 2-Chloroethanol in Sesame Seeds and Other Food Commodities: Challenges and Solutions
Analysis of Ethylene Oxide and 2-Chloroethanol in Sesame Seeds and Other Food Commodities: Challenges and Solutions
- Application Notes
- English
- 23 Jun 2022
- 370.54 KB
- Brochures
- Flyers
- Posters
- Technical Overviews
- FAQs
-
Instrument Detection Limit Frequently Asked Questions (FAQ)
An Introduction to Using Instrument Detection Limit as a Performance Metric
- User Contributed Software
More help is just a click away.
If you didn’t find what you need, try these resources or contact a specialist.
Forensic Toxicology Triple Quadrupole GC/MS MRM Database
A curated set of 1,804 MRM transitions for 176 toxicologically relevant compounds. (For Forensic Use)
GC Productivity Tools
Download method translation software plus calculators for vapor volume, pressure flow, solvent vent, and CFT.
Helium Conservation Cost Savings Calculator
See how much helium and money you could save using Gas Saver and a helium conservation module for nitrogen standby.
Essential Supplies for GC/MS Workflows
These top supplies are recommended by Agilent technical experts to optimize your GC/MS workflows.
Videos
Recent Advances in the Routine Analysis of Dioxins in Food and Environmental Samples
In this webcast we will present how we implemented triple quadrupole GC–MS for the routine analysis of dioxins in environmental and food samples according to EPA and SANTE guidelines. We will discuss technological advances like a high efficiency source, allowing routine testing labs to easily meet regulatory performance criteria set by USEPA 1613 for environmental samples and EU 644/2017 for food samples. Further, we will discuss how the use of hydrogen carrier gas can significantly reduce lab operating costs compared to helium while still meeting regulatory limits of detection.
Agilent Launches New J&W Ultra Inert Columns with Ultra Low-Bleed Technology
The new J&W 5Q columns combine Agilent's industry-leading Ultra Inert performance with Ultra Low-Bleed technology, delivering the new standard for MS column performance and productivity. 5Q columns provide exceptional peak symmetry and minimal column bleed enabling high sensitivity, mass spectral integrity, and accurate quantitation for the most challenging, trace-level analytes. 5Q columns are also designed to optimize sample throughput with fast conditioning and outstanding durability even at high operating temperatures.
- 01 Aug 2024
Agilent ranked in top 20 of Time magazine's 500 most sustainable companies in the world
Sustainability is closely tied to our mission to advance the quality of life. It drives our efforts to be a leading sustainable lab partner to our customers, to work toward a clean-energy future, and to be a top employer of diverse and inclusive talent. We're honored to be ranked in the top 20 of Time magazine's 500 most sustainable companies in the world.
- 22 Jul 2024
eBook Showcases How Agilent GC and GC/MS Systems Can Help Labs Meet Their Sustainability Goals
Access infographics, ACT labels, ESG reports, videos and more to learn how Agilent keeps sustainability in mind during the entire instrument lifecycle, from design to decommissioning. We are dedicated to helping you lower your environmental impact while maintaining lab efficiency and productivity.
- 08 Apr 2024