8860 Gas Chromatograph (GC) System
8860 GC System
Built-in intelligence, intuitive touch screen interface, and cost-effective options such as DA Express and electronic pneumatic regulation (EPR) make the 8860 GC an attractive option, elevating routine gas chromatography analysis to new levels of performance, reliability, and cost effectiveness.
- GC Systems
Request a Quote
Product Details
- Advanced instrument intelligence functionality for GC diagnostics and maintenance helps lab managers better avoid unplanned downtime, minimizing costly operational surprises
- Color touch screen display provides access to GC setpoint and status information, configuration, and signal plot to confirm that analyses are progressing as intended
- Browser user interface provides convenient access from a PC or tablet to edit methods and sequences, access advanced intelligence functions, see instrument status, and run diagnostics from any place within reach of your lab network—even from home
- Blank run evaluation identifies and notifies the user for problems such as baseline excursions, unexpected peaks, and elevated baselines
- Detector evaluation automatically evaluates GC detector checkout samples, providing summary reports in the diagnostic section
- Unique 6th-generation microchannel-based EPC architecture provides a significant improvement in reliability and longevity against gas contaminants such as particulates, water, and oils over previous generation Agilent GC designs, as well as other GC vendors designs
- Full 8860 electronic pneumatics control (EPC)—available on all inlets and detectors—ensures better repeatability of retention times and peak areas, more consistent results, and less rework
- Electronic Pneumatics Regulation (EPR) option provides simple manual operation with high-precision digital display of pressure and flow (actual pressure and flow data can be recorded with Agilent OpenLab CDS software) and offers significant advantages over manual pneumatics systems
- 8860 EPC and EPR ambient temperature and pressure compensation results in more stable retention times and detector baselines
- Optional helium conservation module reduces the amount of helium used and the associated costs
- Optional Hydrogen Sensor Module Series 2 detects hydrogen leaks early and shuts off gas flows, continuously monitors status using built-in intelligent diagnostics, and requires calibration only every six months
- Retention time locking (RTL), available with most Agilent OpenLab CDS software, provides the ability to precisely match chromatographic retention times in any GC system to those in another Agilent GC system with the same method and column
- Optional DA Express Data Analysis for 8860 GC simplifies data analysis, integration, reporting, and calibration making it particularly well suited for users who do not require significant data processing or compliant software functionality
- Autoranging flame ionization detector (FID) provides a wide dynamic response range, enhances accuracy, and minimizes preparation requirements for samples that contain very high or very low compound concentrations
- Single-filament thermal conductivity detector (TCD) provides a stable baseline without drift and does not require a separate reference gas or manual potentiometer adjustment
- Independently audited for environmental impact throughout the product lifecycle, received My Green Labs ACT (Accountability, Consistency, Transparency) label
Capillary Flow Technology (CFT) |
|
Detectors |
|
Dimensions (WxDxH) |
|
Dual Simultaneous Injection |
|
GC Detector MDLs |
|
GC Diagnostics - Leak Check |
|
GC/MS Compatibility |
|
Inlets |
|
Maximum Temperature Ramp Rate |
|
Operating Temperature Range |
|
Oven Cool Down |
|
Peak Area Repeatability |
|
Retention Time Repeatability |
|
Typical Pressure Control |
|
Valves |
|
Helium Conservation Module
A helium conservation module for 8890, 8860, 8850, or 7890 GC systems can drastically reduce your consumption of helium carrier gas and the associated cost, especially when used with Gas Saver. It can be programmed to switch to a different gas (typically nitrogen) when your GC is idle. The module is compatible with any inlet, backflush, and dual simultaneous injections.
Learn MoreGC Intelligence
Built-in GC Intelligence enables you to work smarter with autonomous monitoring, self-guided maintenance procedures, remote connectivity, and other time-saving features that can improve laboratory efficiency.
Learn MoreDA Express for 8860
For simple, routine GC applications that do not require extensive data processing capabilities or compliance support, Agilent DA Express for an Agilent 8860 GC provides simplified data analysis, and makes it easy to integrate signal data, build calibration curves, and create result reports.
Learn MoreRetention Time Locking (RTL)
Retention time locking (RTL) enables the retention times on one Agilent GC or GC/MSD system to be matched exactly on another like system using the same nominal column.
Learn More- Key Literature
-
Agilent 8890, 8860, and 9000 GC Browser Interface: A Tutorial
An introduction to the 8890, 8860, and 9000 GC Browser Interface.
- White Papers
- English
- 15 Apr 2022
- 3.37 MB
- Application Notes
- Brochures
- Data Sheets
- Flyers
- Posters
- Technical Overviews
- FAQs
-
Frequently Asked Questions about Gas Chromatography (GC)
Learn about GC techniques and approaches that can improve performance and productivity, and get information about some of the more common troubleshooting and maintenance procedures for your GC instruments.
- Firmware
- Quick Reference Guides
- Site Preparation Checklists
- Software Utilities
- User Manuals
More help is just a click away
If you didn't find what you need, try these resources or contact a specialist
GC Productivity Tools
Download method translation software plus calculators for vapor volume, pressure flow, solvent vent, and CFT.
GC Firmware Update Utility
Update the firmware on current and older GC systems and accessories, such as autosamplers and headspace samplers.
Helium Conservation Cost Savings Calculator
See how much helium and money you could save using Gas Saver and a helium conservation module for nitrogen standby.
Essential Supplies for Gas Chromatography Systems
Use these recommended supplies for your 8900/8860/8850/Intuvo GC to help you to achieve peak performance.
GC eSelector Tools
Find the appropriate columns, liners, ferrules, septa, and autosampler syringes for your GC methods.
Videos
Expand Your Throughput and Sample Prep Capabilities with the New 160cm PAL3 Series 2 Autosampler
The Agilent PAL3 Series 2 autosampler is now available in a 160cm version, in addition to the 120cm and 85cm options. The longer rail allows up to 50% more sample capacity than its 120cm counterpart and accommodates more tools to automate sample preparation. All PAL3 samplers are fully integrated with MassHunter, OpenLab CDS, ChemStation, and EZChrom software.
- 06 Oct 2024
eBook Showcases How Agilent GC and GC/MS Systems Can Help Labs Meet Their Sustainability Goals
Access infographics, ACT labels, ESG reports, videos and more to learn how Agilent keeps sustainability in mind during the entire instrument lifecycle, from design to decommissioning. We are dedicated to helping you lower your environmental impact while maintaining lab efficiency and productivity.
- 08 Apr 2024