1260 Infinity II Multisampler Ordering Details
To place an order or get more detailed ordering information including prices and availability, contact your local Agilent sales office or distributor or Request a Quote.
Agilent 1260 Infinity II Multisampler Instrument
Description | Product Number | Comments |
1260 Infinity II Multisampler
Designed for low carryover of up to 800 bar, handles well plates and individual sample containers (for example, vials, Eppendorf tubes). Includes:
|
G7167A | |
InfinityLab Sample Thermostat Thermostat unit for 1260 Infinity II Multisampler (G7167A and B). Slide-in device, customer installable. |
G7167A #101 | Thermostat to control sample temperature from 4°C up to 40°C |
InfinityLab Sample Thermostat Upgrade Slide-in thermostat for existing Multisampler instruments. Customer installable. |
G4761A | Requires FW 7.22 or higher. |
1260 Infinity II Dual-Needle Option Offers a second flow path with needle, seat and loop for parallel operation. Default flow path is two 100 µL loops plus one 100 µL analytical head |
G7167A #111 | For alternating quantitative injections, identical loop volumes are required! Variable volumes need to be purchased and added separately. |
1260 Infinity II Multiwash Option Minimizes carryover adding a high-performance pump for three different solvents plus a solvent selection valve. An extra high-pressure flush head is included to allow for active needle seat back flush. |
G7167A #112 |
Multisampler Drawers for the Agilent 1260 Infinity II Multisampler
In the Agilent 1260 Infinity II Multisampler, a mix of drawer types is allowed which, however, needs to result in a total height of eight units (for example, four double-height drawers; three double-height and two single-height drawers; etc). Drawer slots not used must be closed using double-height substitute-drawers. Three double-height substitute-drawers are included with G7167A. Drawers can be easily exchanged or added to the Multisampler onsite.
Description | Product Number | Comments |
Single-Height Drawer (1H) Quantity 2. Each drawer can hold two individual sample containers for: Shallow well plates (96 or 384 well plates) |
G7167A #131 | Maximum setup with single-height drawers is eight per instrument. |
Dual-Height Drawer (2H) Quantity 1. Each drawer can hold two individual sample containers for:
|
G7167A #132 | Maximum setup with double-height drawers is four per instrument. |
Triple-Height Drawer (3H) Quantity 2. Each drawer can hold two individual sample containers for:
|
G7167A #133 | Maximum setup with triple-height drawers is two per instrument |
Analytical Heads and Sample Loops for the Agilent 1260 Infinity II Multisampler
The Agilent 1260 Infinity II Multisampler offers great flexibility in sample injection volumes. Different options exist for standard (single-needle) instruments and dual-needle equipped instruments (option #111). Standard (single-needle) instruments always use the right-side flow path (for example, loop-right). Dual-needle instruments require two loops and needles (right and left).
Description | Product Number | Comments |
Analytical Head 40 µL 40 µL metering device for use at up to 800 bar. |
G7167A #162 | If only small injection volumes are used this will reduce delay volumes |
Analytical Head 900 µL 900 µL metering device for large single stroke injections at max 400 bar. |
G7167A #163 |
Only for single needle setup. Limits system pressure to 400 bar. |
Sample Loop-Flex 20 µL Right (only for single-needle) For maximum 20 µL injection. |
G7167A #148 | Decrease delay volume of a default 100 µL loop. |
Loop 20 µL Right Dual-Needle Calibrated dual-needle loop right. |
G7167A #143 | Decrease delay volume of a default 100 µL dual-needle loop. |
Loop 20 µL Left Dual-Needle Calibrated dual-needle loop left. |
G7167A #149 | Decrease delay volume of a default 100 µL loop. |
Sample Loop-Flex 40 µL Right (only for single-needle) For maximum 40 µL injection. |
G7167A #150 | Decrease delay volume of a default 100 µL loop. |
Loop 40 µL Right Dual-Needle Calibrated dual-needle loop right. |
G7167A #144 | Decrease delay volume of a default 100 µL dual-needle loop. |
Loop 40 µL Left Dual-Needle Calibrated dual-needle loop left. |
G7167A #151 | Decrease delay volume of a default 100 µL dual-needle loop. |
Sample Loop-Flex 500 µL Right(only for single-needle) For maximum 500 µL injection.
|
G7167A #154 | Extending sample loop volume for standard path. Requires G7167A #163. |
Loop Kit 500 µL Right Dual-Needle Calibrated dual-needle loop-flex plus extension and slotted needle. |
G7167A #146 |
Only within dual-needle setup. Requires a 100 µL analytical head. |
Loop Kit 500 µL Left Dual-Needle Calibrated dual-needle loop-flex plus extension and slotted needle. |
G7167A #155 | Only within dual-needle setup. Requires a 100 µL analytical head. |
Sample Loop-Flex 900 µL Right (only for single-needle) Sample loop-flex 900 µL right for maximum 900 µL injection.
|
G7167A #156 | Requires a 900 µL analytical head (G7167A #163). System pressure limited to maximum 400 bar. |
Loop Kit 900 µL Right Dual-Needle Calibrated dual-needle flex-loop plus extension and slotted needle. |
G7167A #147 | |
Loop Kit 900 µL Left Dual-Needle Calibrated dual-needle flex-loop plus extension and slotted needle. |
G7167A #157 |