201702-100 | Glass fiber | 5 µm | 2 | L | 96 | Agilent polypropylene 96-well filter microplate with 5 µm glass fiber membrane, 2 ml/well, long drip, case of 25, recommended receiver plate 201240-100 |
201007-100 | Glass fiber | 0.7 µm | 2 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.7 µm glass fiber membrane, 2 ml/well, long drip, case of 25, recommended receiver plate 201240-100 |
201719-100 | Glass fiber | 0.7 µm | 1 | L | 96 | Agilent polypropylene 96-well half skirt filter microplate with 4 layers of 0.7 µm glass fiber membrane, 1 ml/well, long drip with turbine, case of 25, recommended receiver plate 201276-100 |
201720-100 | Glass fiber | 0.7 µm | 1 | L | 96 | Agilent polypropylene 96-well half skirt filter microplate with 25 µm polyethylene frit plus 2 layers of 0.7 µm glass fiber membrane, 1 ml/well, long drip with turbine, case of 25, recommended receiver plate 201276-100 |
200929-100 | Glass fiber | 1.2 µm | 0.8 | L | 96 | Agilent polypropylene 96-well filter microplate with 1.2 µm glass fiber membrane, 800 µl/well, long drip, case of 25, recommended receiver plate 201276-100 |
200957-100 | Glass fiber | 1.2 µm | 0.8 | S | 96 | Agilent polypropylene 96-well filter microplate with 1.2 µm glass fiber membrane, 800 µl/well, short drip, case of 25, recommended receiver plate 201276-100 |
200935-100 | Glass fiber | 1 µm | 0.8 | L | 96 | Agilent polypropylene 96-well filter microplate with 1.0 µm glass fiber membrane, 800 µl/well, long drip, case of 25, recommended receiver plate 201276-100 |
200963-100 | Glass fiber | 1 µm | 0.8 | S | 96 | Agilent polypropylene 96-well filter microplate with 1.0 µm glass fiber membrane, 800 µl/well, short drip, case of 25, recommended receiver plate 201276-100 |
200937-100 | Glass fiber | 0.7 µm | 0.8 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.7 µm glass fiber membrane, 800 µl/well, long drip, case of 25, recommended receiver plate 201276-100 |
200941-100 | Glass fiber | 1.2 µm | 0.4 | L | 96 | Agilent polypropylene 96-well filter microplate with 1.2 µm glass fiber membrane, 400 µl/well, long drip, case of 25, recommended receiver plate 204600-100 |
200969-100 | Glass fiber | 1.2 µm | 0.4 | S | 96 | Agilent polypropylene 96-well filter microplate with 1.2 µm glass fiber membrane, 400 µl/well, short drip, case of 25, recommended receiver plate 204600-100 |
200975-100 | Glass fiber | 1 µm | 0.4 | S | 96 | Agilent polypropylene 96-well filter microplate with 1.0 µm glass fiber membrane, 400 µl/well, short drip, case of 25, recommended receiver plate 204600-100 |
200951-100 | Glass fiber | 0.7 µm | 0.4 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.7 µm glass fiber membrane, 400 µl/well, long drip, case of 25, recommended receiver plate 204600-100 |
200977-100 | Glass fiber | 0.7 µm | 0.4 | S | 96 | Agilent polypropylene 96-well filter microplate with 0.7 µm glass fiber membrane, 400 µl/well, short drip, case of 25, recommended receiver plate 204600-100 |
201021-100 | Glass fiber | 3 µm | 0.3 | L | 96 | Agilent polypropylene 96-well filter microplate with 3 µm glass fiber membrane, 300 µl/well, long drip, case of 50, recommended receiver plate 203942-100 |
200985-100 | Glass fiber | 1 µm | 0.3 | L | 96 | Agilent polypropylene 96-well filter microplate with 1.0 µm glass fiber membrane, 300 µl/well, long drip, case of 50, recommended receiver plate 203942-100 |
200987-100 | Glass fiber | 0.7 µm | 0.3 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.7 µm glass fiber membrane, 300 µl/well, long drip, case of 50, recommended receiver plate 203942-100 |
201001-100 | Glass fiber | 0.7 µm | 0.3 | S | 96 | Agilent polypropylene 96-well filter microplate with 0.7 µm glass fiber membrane, 300 µl/well, short drip, case of 50, recommended receiver plate 203942-100 |
201033-100 | Glass fiber | 5 µm | 0.14 | L | 384 | Agilent polypropylene 384-well filter microplate with 5 µm glass fiber membrane, 140 µl/well, long drip, case of 10, recommended receiver plate 204586-100 |
201025-100 | Glass fiber | 1.2 µm | 0.14 | L | 384 | Agilent polypropylene 384-well filter microplate with 1.2 µm glass fiber membrane, 140 µl/well, long drip, case of 10, recommended receiver plate 204586-100 |
201027-100 | Glass fiber | 0.7 µm | 0.14 | L | 384 | Agilent polypropylene 384-well filter microplate with 0.7 µm glass fiber membrane, 140 µl/well, long drip, case of 10, recommended receiver plate 204586-100 |
201003-100 | Polyethylene | 25 µm | 7.5 | L | 48 | Agilent polypropylene 48-well filter microplate with 25 µm polyethylene frit, 7.5 ml/well, long drip, case of 15, recommended receiver plate 201236-100 |
200923-100 | Polyethylene | 25 µm | 5 | L | 48 | Agilent polypropylene 48-well filter microplate with 25 µm polyethylene frit, 5 ml/well, long drip, case of 25, recommended receiver plate 201238-100 |
200925-100 | Polyethylene | 25 µm | 5 | XL | 48 | Agilent polypropylene 48-well filter microplate with 25 µm polyethylene frit, 5 ml/well, EXTRA long drip, case of 25, recommended receiver plate 201238-100 |
200919-100 | Polyethylene | 25 µm | 2 | L | 96 | Agilent polypropylene 96-well filter microplate with 25 µm polyethylene frit, 2 ml/well, long drip, case of 25, recommended receiver plate 201240-100 |
201005-100 | Polyethylene | 25 µm | 2 | L | 96 | Agilent polypropylene 96-well filter microplate with 25 µm ultra high molecular weight polyethylene membrane, 2 ml/well, long drip, case of 25, recommended receiver plate 201240-100 |
200921-100 | Polyethylene | 25 µm | 2 | XL | 96 | Agilent polypropylene 96-well filter microplate with 25 µm polyethylene frit, 2 ml/well, EXTRA long drip, case of 25, recommended receiver plate 201240-100 |
201718-100 | Polyethylene | 25 µm | 1 | L | 96 | Agilent polypropylene 96-well half skirt filter microplate with 25 µm polyethylene frit, 1 ml/well, long drip with turbine, case of 25, recommended receiver plate 201276-100 |
200927-100 | Polyethylene | 25 µm | 0.8 | L | 96 | Agilent polypropylene 96-well filter microplate with 25 µm high molecular weight polyethylene membrane, 800 µl/well, long drip, case of 25, recommended receiver plate 201276-100 |
200955-100 | Polyethylene | 25 µm | 0.8 | S | 96 | Agilent polypropylene 96-well filter microplate with 25 µm high molecular weight polyethylene membrane, 800 µl/well, short drip, case of 25, recommended receiver plate 201276-100 |
200953-100 | Polyethylene | 25 µm | 0.8 | L | 96 | Agilent polypropylene 96-well filter microplate with 25 µm polyethylene frit, 800 µl/well, long drip, case of 25, recommended receiver plate 201276-100 |
201019-100 | Polyethylene | 25 µm | 0.8 | L | 96 | Agilent polypropylene 96-well filter microplate with 65 µm polyethylene frit plus 0.7 µm glass fiber membrane, 800 µl/well, long drip, case of 25, recommended receiver plate 201276-100 |
202501-100 | Polyethylene | 7 µm | 0.8 | S | 96 | Agilent polypropylene 96-well filter microplate with 7 µm polyethylene frit, 800 µl/well, short drip, case of 25, recommended receiver plate 201276-100 |
200939-100 | Polyethylene | 25 µm | 0.4 | L | 96 | Agilent polypropylene 96-well filter microplate with 25 µm high molecular weight polyethylene membrane, 400 µl/well, long drip, case of 25, recommended receiver plate 204600-100 |
200967-100 | Polyethylene | 25 µm | 0.4 | S | 96 | Agilent polypropylene 96-well filter microplate with 25 µm high molecular weight polyethylene membrane, 400 µl/well, short drip, case of 25, recommended receiver plate 204600-100 |
200979-100 | Polyethylene | 25 µm | 0.4 | S | 96 | Agilent polypropylene 96-well filter microplate with 25 µm polyethylene frit, 400 µl/well, short drip, case of 25, recommended receiver plate 204600-100 |
200991-100 | Polyethylene | 25 µm | 0.3 | S | 96 | Agilent polypropylene 96-well filter microplate with 25 µm high molecular weight polyethylene membrane, 300 µl/well, short drip, case of 50, recommended receiver plate 204600-100 |
200989-100 | Polyethylene | 25 µm | 0.3 | L | 96 | Agilent polypropylene 96-well filter microplate with 25 µm high molecular weight polyethylene membrane, 300 µl/well, long drip, case of 50, recommended receiver plate 204600-100 |
201035-100 | Polyethylene | 25 µm | 0.14 | L | 384 | Agilent polypropylene 384-well filter microplate with 25 µm polyethylene frit, 140 µl/well, long drip, case of 10, recommended receiver plate 204586-100 |
201031-100 | No Filter | N/A | 0.14 | L | 384 | Agilent polypropylene 384-well filter microplate with NO FILTER, 140 µl/well, long drip, case of 10, recommended receiver plate 204586-100 |
201415-100 | Polyethylene | 25 µm | 15 | L | 24 | Agilent polypropylene 24-well filter microplate with 25 µm polyethylene frit, 15 ml/well, long drip, case of 15, recommended receiver plate 202061-100 |
204471-100 | Polyethylene | 25 µm | 10 | L | 24 | Agilent Microplates polypropylene 24-well filter microplate with 25 micrometer polyethylene membrane, 10 milliter per well, long drip, case of 25 |
203982-100 | Polyvinylidene fluoride | 0.2 µm | 0.8 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.2 µm polyvinylidene fluoride membrane, 800 µl/well, long drip, case of 25, recommended receiver plate 201276-100 (204355-100 irradiated) |
200931-100 | Polyvinylidene fluoride | 0.45 µm | 0.8 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polyvinylidene fluoride membrane, 800 µl/well, long drip, case of 25, recommended receiver plate 201276-100 (204355-100 irradiated) |
200959-100 | Polyvinylidene fluoride | 0.45 µm | 0.8 | S | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polyvinylidene fluoride membrane, 800 µl/well, short drip, case of 25, recommended receiver plate 201276-100 (204355-100 irradiated) |
203980-100 | Polyvinylidene fluoride | 0.2 µm | 0.4 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.2 µm polyvinylidene fluoride membrane, 400 µl/well, long drip, case of 25, recommended receiver plate 204600-100 (204601-100 irradiated) |
200943-100 | Polyvinylidene fluoride | 0.45 µm | 0.4 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polyvinylidene fluoride membrane, 400 µl/well, long drip, case of 25, recommended receiver plate 204600-100 (204601-100 irradiated) |
200971-100 | Polyvinylidene fluoride | 0.45 µm | 0.4 | S | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polyvinylidene fluoride membrane, 400 µl/well, short drip, case of 25, recommended receiver plate 204600-100 (204601-100 irradiated) |
201023-100 | Polyvinylidene fluoride | 1 µm | 0.3 | S | 96 | Agilent polypropylene 96-well filter microplate with 1.0 µm HYDROPHOBIC polyvinylidene fluoride membrane on a polypropylene support, 300 µl/well, short drip, case of 50, recommended receiver plate 203942-100 |
200981-100 | Polyvinylidene fluoride | 0.45 µm | 0.3 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polyvinylidene fluoride membrane, 300 µl/well, long drip, case of 50, recommended receiver plate 203942-100 (204602-100 irradiated) |
200995-100 | Polyvinylidene fluoride | 0.45 µm | 0.3 | S | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polyvinylidene fluoride membrane, 300 µl/well, short drip, case of 50, recommended receiver plate 203942-100 (204602-100 irradiated) |
204463-100 | Polyvinylidene fluoride | 0.45 µm | 10 | L | 24 | Agilent Microplates polypropylene 24-well filter microplate with 0.45 micrometer polyvinylidene fluroride membrane, 10 milliter per well, long drip, case of 25, recommended receiver plate 201272-100 (204023-100 irradiated) |
204465-100 | Polyvinylidene fluoride | 0.2 µm | 10 | L | 24 | Agilent Microplates polypropylene 24-well filter microplate with 0.2 micrometer polyvinylidene fluroride menbrane, 10 milliter per well, long drip, case of 25, recommended receiver plate 201272-100 (204023-100 irradiated) |
201009-100 | Polypropylene | 0.45 µm | 2 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polypropylene membrane, 2 ml/well, long drip, case of 25, recommended receiver plate 201240-100 (204353-100 irradiated) |
200933-100 | Polypropylene | 0.45 µm | 0.8 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polypropylene membrane, 800 µl/well, long drip, case of 25, recommended receiver plate 201276-100 (204355-100 irradiated) |
200961-100 | Polypropylene | 0.45 µm | 0.8 | S | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polypropylene membrane, 800 µl/well, short drip, case of 25, recommended receiver plate 201276-100 (204355-100 irradiated) |
200945-100 | Polypropylene | 0.45 µm | 0.4 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polypropylene membrane, 400 µl/well, long drip, case of 25, recommended receiver plate 204600-100 (204601-100 irradiated) |
200973-100 | Polypropylene | 0.45 µm | 0.4 | S | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polypropylene membrane, 400 µl/well, short drip, case of 25, recommended receiver plate 204600-100 (204601-100 irradiated) |
200983-100 | Polypropylene | 0.45 µm | 0.3 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polypropylene membrane, 300 µl/well, long drip, case of 50, recommended receiver plate 203942-100 (204602-100 irradiated) |
200997-100 | Polypropylene | 0.45 µm | 0.3 | S | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polypropylene membrane, 300 µl/well, short drip, case of 50, recommended receiver plate 203942-100 (204602-100 irradiated) |
201011-100 | Polyethersulfone | 0.45 µm | 2 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polyethersulphone membrane, 2 ml/well, long drip, case of 25, recommended receiver plate 201240-100 (204353-100 irradiated) |
201013-100 | Polyethersulfone | 10 kDa | 0.4 | S | 96 | Agilent polypropylene 96-well filter microplate with 10 kDa polyethersulfone membrane, 400 µl/well, short drip, case of 25, recommended receiver plate 204600-100 (204601-100 irradiated) |
201015-100 | Polyethersulfone | 30 kDa | 0.4 | S | 96 | Agilent polypropylene 96-well filter microplate with 30 kDa polyethersulfone membrane, 400 µl/well, short drip, case of 25, recommended receiver plate 204600-100 (204601-100 irradiated) |
201596-100 | Polyethersulfone | 100 kDa | 0.4 | S | 96 | Agilent polypropylene 96-well filter microplate with 100 kDa polyethersulfone membrane, 400 µl/well, short drip, case of 25, recommended receiver plate 204600-100 (204601-100 irradiated) |
201598-100 | Polyethersulfone | 300 kDa | 0.4 | S | 96 | Agilent polypropylene 96-well filter microplate with 300 kDa polyethersulfone membrane, 400 µl/well, short drip, case of 25, recommended receiver plate 204600-100 (204601-100 irradiated) |
203940-100 | Polyethersulfone | 0.2 µm | 0.4 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.2 µm polyethersulphone membrane, 400 µl/well, long drip, case of 25, recommended receiver plate 204600-100 (204601-100 irradiated) |
204469-100 | Polyethersulfone | 0.2 µm | 10 | L | 24 | Agilent Microplates polypropylene 24-well filter microplate with 0.2 micrometer polyether sulfone menbrane, 10 milliter per well, long drip, case of 25, recommended receiver plate 201272-100 (204023-100 irradiated) |
204467-100 | Polyethersulfone | 0.45 µm | 10 | L | 24 | Agilent Microplates polypropylene 24-well filter microplate with 0.45 micrometer polyether sulfone menbrane, 10 milliter per well, long drip, case of 25, recommended receiver plate 201272-100 (204023-100 irradiated) |
201738-100 | Nylon | 0.45 µm | 0.3 | S | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm nylon membrane, 300 µl/well, short drip, case of 50, recommended receiver plate 203942-100 (204602-100 irradiated) |
203846-100 | Protein precipitation | 0.7 µm | 2 | L | 96 | Agilent polypropylene 96-well filter microplate for protein precipitation, 1.8 ml/well, long drip, includes a receiver plate 201240-100 and lid 200856-100, case of 1 kit |
202951-100 | No Filter | N/A | 2 | XL | 96 | Agilent polypropylene 96-well filter microplate with NO FILTER, EXTRA long drip, case of 25, recommended receiver plate 201240-100 |
201537-100 | Glass fiber | 0.7 µm | 0.8 | L | 96 | Agilent polypropylene 96-well filter microplate with 4X 0.7 µm glass fiber membranes, 800 µl/well, long drip, case of 25, recommended receiver plate 201276-100 |
201731-100 | Polyvinylidene fluoride | 0.45 µm | 2 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.45 µm polyvinylidene fluoride membrane, 2 mL/well, long drip, case of 25, recommended receiver plate 201240-100 |
202400-100 | Glass fiber | 7 µm | 0.4 | L | 96 | Agilent polypropylene 96-well filter microplate with 7.0 µm glass fiber membrane, 400 µl/well, long drip, case of 25, recommended receiver plate 204600-100 |
204474-100 | Glass fiber | 1.2 µm | 10 | L | 24 | Agilent Microplates polypropylene 24-well filter microplate with 1.2 micrometer glass fiber menbrane, 10 milliter per well, long drip, case of 25, recommended receiver plate 201272-100 |
204495-100 | Glass fiber | 3 µm | 2 | L | 96 | Agilent polypropylene 96-well filter microplate with 3 µm glass fiber + 25 µm polyethylene support membranes, 2 ml/well, long drip, case of 25, recommended receiver plate 201240-100 |
204510-100 | Polyethersulfone | 0.2 µm | 2 | L | 96 | Agilent polypropylene 96-well filter microplate with 0.2µm polyethersulphone membrane, 2mL/well, long drip, case of 25, recommended receiver plate 201240-100 (204353-100 irradiated) |